Press ESC or click anywhere outside to close

5 in 1 Pool Dehumidification Heat Pump

Coordinate humidity, room temperature, pool water, outdoor air and recovered heat in one engineered indoor-pool system. Designed for commercial facilities where comfort, ventilation and energy routing must work together.

Dehumidification Air Cooling / Heating Pool Water Heating Fresh Air / Exhaust Air Heat Recovery
Complete Pool-Hall System Image
AIR LOOPReturn → Treat → Supply
VENTILATIONFresh Air ↔ Exhaust Air
WATER LOOPRecovered Heat → Pool

Product structure

Show the physical equipment before the model table. Three equally sized images help buyers assess construction, maintenance access and control capability.

Five functions managed as one system

Integrated control responds to humidity, air temperature, water demand and ventilation conditions so individual components do not fight each other.

01

Dehumidification

Removes latent moisture to control room dew point.

02

Air Cooling / Heating

Adjusts room sensible temperature across seasonal modes.

03

Pool Water Heating

Routes available heat to the pool-water circuit.

Integrated Control Core Sensors, mode logic, fan control, refrigeration circuit and project interfaces
04

Fresh Air / Exhaust Air

Coordinates designed outdoor air and exhaust paths.

05

Heat Recovery

Reuses available energy from dehumidification and exhaust processes for supply-air treatment or pool-water heating, subject to the selected configuration and simultaneous loads.

Make every air path visible

A commercial natatorium needs more than a dehumidifier. Return air, treated supply air, outdoor air and exhaust air must be balanced with the pressure and ventilation strategy developed by the MEP designer.

RETURNCollect humid room air from the designed high-moisture zones.
TREATFilter, dehumidify and cool or reheat according to demand.
SUPPLYDeliver conditioned air to glazing and occupied zones with adequate throw.
VENTCoordinate fresh-air intake and exhaust volume with the project schedule.
Internal Component Layout
Return Air Supply Air Fresh Air Exhaust Air

Final airflow, outdoor-air rate, pressure relationship and duct arrangement must comply with local codes and the approved mechanical design.

A 5 in 1 system needs four groups of project data

Capacity, airflow and control sequences are interdependent. Sending complete inputs early reduces model reselection and late duct or plant-room changes.

Pool Load
  • Surface area and connected spas
  • Water temperature
  • Activity and occupancy
  • Pool cover schedule
  • Water-heating requirement
Room Load
  • Room volume and design RH
  • Indoor air temperature
  • Glazing and envelope data
  • Lighting and people load
  • Summer sensible cooling load
Ventilation
  • Outdoor design conditions
  • Required fresh-air volume
  • Exhaust and pressure strategy
  • Duct static pressure
  • Supply and return arrangement
Controls
  • Occupied/unoccupied schedule
  • Air and water priorities
  • BMS protocol requirement
  • Remote alarm points
  • Power supply and standards
Send drawings before equipment is frozen We can review preliminary latent load, airflow, heat routing and interface requirements.
Request Engineering Review →

Commercial pool projects need visible proof

Use three equally sized installation photographs—never small thumbnails or a carousel—so consultants and contractors can inspect the application at a glance.

Data needed for selection

Pool load · room load · outdoor air · exhaust strategy · duct static pressure · air/water priorities · BMS points

Send Project Drawings →

Preliminary commercial selection range

Replace starred values with final model data, rated test conditions, fan curves, sound data and approved communication options before the page goes live.

Dehumidification Capacity*
10–80 kg/h
Nominal Airflow*
3,000–20,000 m³/h
Pool Water Heating Capacity*
20–150 kW
Air Cooling Capacity*
15–120 kW
Air Heating Capacity*
20–150 kW
Fresh-Air Ratio*
Project-configured; up to 30% reference
Available External Static Pressure*
300–800 Pa
Control / BMS*
Touch controller; Modbus / BACnet optional
Refrigerant
Confirm by selected model and target market

* Preliminary reference values for page layout only; not a performance guarantee. Actual capacity depends on entering air, water temperature, outdoor-air ratio, airflow and operating mode.

5 in 1 Pool Dehumidifier FAQ

Resolve the main system questions before tender comparison or final equipment selection.

Discuss Your Pool Project →
What is the difference between the 3 in 1 and 5 in 1 series?
The 3 in 1 series focuses on dehumidification, air heating and pool-water heating. The 5 in 1 series adds active air cooling/heating coordination, fresh-air/exhaust-air management and broader heat-recovery control for commercial projects with more complex ventilation and seasonal loads.
Can the unit control negative pressure in the pool hall?
It can coordinate configured supply, fresh-air and exhaust-air volumes, but the required pressure relationship must be designed and commissioned for the whole building. Door leakage, adjacent spaces, independent exhausts, duct balancing and local code requirements all affect the result.
Is the outdoor-air rate fixed?
No. Outdoor-air quantity should follow occupancy, air quality, local codes and the approved mechanical schedule. If a variable fresh-air ratio is required, provide the minimum/maximum airflow, control signal and corresponding external static pressure during selection.
What information is required to confirm heat-recovery performance?
Provide return and outdoor design conditions, exhaust and fresh-air volumes, pool-water temperatures, air-side heating/cooling loads and the intended operating sequence. Heat available from dehumidification or exhaust air changes with mode and simultaneous demand.
Which OEM options are available for distributors and project orders?
Subject to order volume, engineering feasibility and certification scope, options may include branding, cabinet arrangement, airflow direction, filter grade, controller language, communication interface, packaging and documentation. Share the target market, annual volume and mandatory standards for review.

Partner With Cassky for Reliable Clean Energy Solutions

Cassky specializes in high-performance heat pump systems and solar energy solutions, providing reliable products and customized services for global distributors, engineering companies, contractors, and brand partners.

1. Distributors & Dealers Build long-term partnerships with reliable heat pump and solar energy products, competitive supply capability, and professional support.
2. Engineering Companies & Contractors Get technical assistance, project solutions, and product recommendations for residential and commercial energy projects.
3. OEM / Brand Partners Access customized manufacturing, private label solutions, and flexible cooperation options for your market.

Request a Quote

Tell us about your product or project requirements. Our team will contact you to discuss the next step.

Request a Quote