Press ESC or click anywhere outside to close

Home / Evacuated-Tube Solar Water Heater  /  Evacuated-Tube Solar collector Water Heater

Evacuated-Tube Solar Water Heater

Configurable integrated and pressurized systems

A vacuum-tube solar hot-water platform configurable for different tank capacities, climates, installation requirements and target markets. Cassky supports private labeling, component selection and flexible production scheduling for distributors, project buyers and growing brands.

Cassky evacuated-tube solar water heater
100–300 L* Common configurable tank range
10–30 Tubes* Matched to capacity and design
Ø58 × 1800 mm* Common evacuated-tube format
Flexible OEM Branding, finish and packaging options

*Preliminary market-reference ranges compiled from comparable manufacturer and supplier specifications. Final Cassky values must be confirmed against the selected construction, pressure type and approved technical sheet before publication.

How an Evacuated-Tube Solar Water Heater Works

Each double-wall glass tube captures solar radiation while its vacuum layer limits heat loss. Collected heat is transferred to the storage system, producing hot water with little or no conventional energy during suitable solar conditions.

Evacuated-Tube Solar Water Heater System Diagram
01 / CAPTURE

Solar Energy Absorption

The selective coating inside each evacuated tube absorbs sunlight and converts it into thermal energy.

02 / RETAIN

Reduced Heat Loss

The vacuum between the glass layers reduces conduction and convection losses, supporting heat collection in cooler conditions.

03 / TRANSFER

Heat Moves to the Tank

Depending on the selected system, heat is transferred through direct thermosiphon circulation, a heat pipe or an indirect coil.

04 / STORE

Insulated Hot-Water Storage

A polyurethane-insulated tank stores the heated water for domestic, hospitality or light-commercial use.

Sunlight Evacuated Tubes Heat Transfer Insulated Tank Hot Water

Select the System Architecture for Your Market

Pressure conditions, climate, installation habits and local price positioning determine the right configuration. Cassky can develop a matched product family instead of forcing every market into one standard model.

Non-Pressurized Compact System

Direct Thermosiphon System

A simple rooftop configuration in which water circulates naturally between the evacuated tubes and storage tank.

  • Simple construction
  • Low electrical dependence
  • Suitable for gravity-fed applications
Compact Pressurized System

Heat-Pipe Pressurized System

Heat pipes transfer solar energy to a pressurized tank circuit without allowing domestic water to flow through the glass tubes.

  • Pressurized hot-water delivery
  • Individual tube serviceability
  • Premium residential positioning
Pre-Heated / Coil System

Indirect Heat-Exchange System

An internal coil or separated circuit can be configured for mains-pressure preheating and selected cold-climate requirements.

  • Indirect water heating
  • Flexible hydraulic integration
  • Project-specific configuration
Not sure which version fits your market? Send the local water pressure, winter temperature, preferred capacity, target price level and annual order forecast.
Ask for Configuration Support  →

Designed for Efficient Collection and Practical Market Deployment

The value of an evacuated-tube system comes from more than solar absorption. Product architecture, packaging, serviceability and configuration consistency all influence distributor success.

01

Vacuum-Layer Heat Retention

The evacuated space around the absorber helps limit heat loss compared with an uninsulated exposed absorber.

More useful heat under variable conditions.
02

Modular Tube Configuration

Tube quantity can be matched to tank capacity, expected demand and the intended market position.

A scalable product family from one platform.
03

Low Operating Energy

Passive thermosiphon versions require little operating electricity, while controllers and backup heaters remain optional.

A clear energy-saving sales proposition.
04

Insulated Water Storage

High-density polyurethane insulation helps retain collected heat between solar collection and hot-water use.

Improved hot-water availability.
05

Replaceable Components

Vacuum tubes, controllers, sensors and selected accessories can be supplied as service parts according to the configuration.

Easier distributor after-sales support.
06

Market-Specific Construction

Tank material, casing finish, frame, pressure type and packaging can be aligned with local expectations.

Better product-market fit.

Technical Specifications

Request Confirmed Datasheet
Market-reference ranges for preliminary product planning
Item Common Range / Option Configuration Notes
Nominal Tank Capacity 100 / 150 / 180 / 200 / 240 / 250 / 300 L Final usable volume and model sequence require confirmation.
Evacuated Tube Quantity 10–30 tubes Matched to tank capacity, architecture and target performance.
Common Tube Size Ø58 × 1800 mm Alternative tube formats may be evaluated for volume orders.
System Type Non-pressure / pressurized / indirect Select according to water pressure, climate and installation practice.
Inner Tank SUS304 or market-specific option Material grade and thickness must be stated in the quotation.
Outer Casing Stainless steel / coated steel Finish, color and corrosion requirements are configurable.
Thermal Insulation Approx. 50 mm PU foam Final density and thickness depend on the selected tank design.
Frame Galvanized or coated steel Roof angle, wind load and corrosion environment require review.
Working Pressure Configuration-dependent Non-pressure and pressurized products must not share one pressure rating.
Electric Backup Optional Power, voltage, plug and thermostat depend on destination market.
Controller & Sensors Optional Display, functions and language can be selected by model.
Heat Exchanger Optional internal coil Coil material and surface area require project confirmation.
Branding OEM / private label Logo, label, packaging and documentation subject to order terms.
Important: These are preliminary ranges synthesized from comparable supplier and manufacturer specifications, including commonly published 100–300 L tanks, 10–30 tubes, Ø58 × 1800 mm tubes and approximately 50 mm insulation. They are not a final Cassky datasheet. Publish exact pressure, materials, dimensions, performance, certification and warranty only after engineering and commercial approval.

A Configurable Solar Hot-Water Platform for Different Channels

The final product should be selected from actual daily hot-water demand, local solar conditions, available roof area, water pressure and backup-heating strategy—not capacity alone.

Homes & Villas

Homes & Villas

Domestic bathing and general hot-water supply with capacity matched to occupancy.

Hotels & Guesthouses

Hotels & Guesthouses

Multiple-unit or preheating arrangements for hospitality hot-water demand.

Dormitories & Camps

Dormitories & Camps

Distributed hot-water production for accommodation and staff facilities.

Dealers & Retail Programs

Dealers & Retail Programs

A capacity series configured for local installation practices and price segments.

Information Needed for Selection

Providing complete project and market inputs helps reduce configuration changes after quotation and makes the recommended system more commercially realistic.

01 Country, climate and winter temperature
02 Daily hot-water volume and users
03 Water pressure and water quality
04 Roof type, area and orientation
05 Backup-heating requirement
06 Target quantity and delivery plan
Final sizing and installation must be reviewed by qualified local solar-thermal, plumbing and structural professionals. Request Project Review  →

Frequently Asked Questions

Common questions from distributors, private-label buyers and project purchasers evaluating evacuated-tube solar water heaters.

01What capacities can be supplied?+

Comparable market products commonly cover 100–300 L, with intermediate sizes such as 150, 180, 200, 240 and 250 L. Cassky availability must be confirmed by system type, tank construction and order quantity.

02How many evacuated tubes should a system use?+

Tube quantity is normally matched to tank capacity and expected solar input. Common comparable configurations use approximately 10–30 tubes, but final selection must consider climate, demand and tube specification.

03Can you supply both pressurized and non-pressurized versions?+

They can be developed as separate product configurations. The hydraulic architecture, tank construction, safety devices and ratings must be confirmed independently for each version.

04What can be customized for OEM orders?+

Options may include capacity, tube quantity, tank and casing material, color, frame, controller, electric backup, heat exchanger, logo, rating label, manual and packaging. Availability depends on technical feasibility and order terms.

05Do you support small trial orders?+

A pilot-order arrangement can be discussed for suitable standard or lightly customized products. MOQ and pricing depend on materials, tooling, branding and packaging requirements.

06How does flexible production scheduling work?+

Buyers can provide a rolling forecast and discuss pilot production, confirmed batch releases, phased shipments or seasonal capacity planning. Every schedule remains subject to purchase-order confirmation and current production capacity.

07Can the system work in freezing climates?+

Cold-climate suitability depends on system architecture, heat-transfer fluid, pipe routing, controls and freeze-protection design. A project-specific review is necessary; vacuum tubes alone do not make the complete installation freeze-proof.

08What information is required for a quotation?+

Please provide destination country, required capacity, estimated quantity, pressure type, preferred materials, electrical standard, branding needs, packaging requirements and delivery schedule.

Build the right solar water heater for your market. Send your product brief, target price level and purchasing forecast for configuration and OEM review.
Request a Quote  →

Partner With Cassky for Reliable Clean Energy Solutions

Cassky specializes in high-performance heat pump systems and solar energy solutions, providing reliable products and customized services for global distributors, engineering companies, contractors, and brand partners.

1. Distributors & Dealers Build long-term partnerships with reliable heat pump and solar energy products, competitive supply capability, and professional support.
2. Engineering Companies & Contractors Get technical assistance, project solutions, and product recommendations for residential and commercial energy projects.
3. OEM / Brand Partners Access customized manufacturing, private label solutions, and flexible cooperation options for your market.

Request a Quote

Tell us about your product or project requirements. Our team will contact you to discuss the next step.

Request a Quote